Rinnai Tankless Error Codes: What They Mean and How to Fix Them

Disclosure: As an Amazon Associate, Sweet Home Advisor earns from qualifying purchases. If you buy through links on this page, we may earn a small commission at no extra cost to you.

Rinnai tankless water heaters show a number or letter code on the temperature controller when something goes wrong. The most common ones homeowners see are 11 (no ignition), 12 (flame failure), 10 (venting or air supply problem), LC (scale buildup, time to flush) and 25 (condensate drain blocked). Many can be cleared with a simple check and reset, but anything involving gas parts, sensors or the circuit board should be handled by a qualified technician.

Before you start

  • Basic reset: turn off the hot water taps, then press the On/Off button on the controller off and on. Rinnai’s guide suggests repeating a reset up to a few times before calling for service.
  • Smell gas? Leave the house and call your gas company from outside.
  • Servicing: Rinnai’s diagnostic guide is written for qualified technicians, and internal repairs require turning off power, gas and water first.

Rinnai error codes chart

Code Meaning What you can check Call a pro if
LC (LC0 to LC9) Scale buildup in the heat exchanger Flush the heat exchanger (see below); treat hard water You can’t flush it yourself
SS “Service Soon” maintenance reminder Flush the heat exchanger and service the unit  
05 Bypass flow control fault Reset Code returns
10 Air supply or exhaust problem Check vent terminations outside for blockage (snow, leaves, nests); make sure the condensate drain flows; clean the air filter Vent looks clear but code persists
11 No ignition Make sure the gas supply valve is open and other gas appliances work; reset Gas is on and code persists
12 Flame failure (flame lost) Check gas supply; check that vents aren’t blocked; reset Code repeats
14 Overheat or thermal fuse tripped Reset once Always investigate; may need heat exchanger flush or parts
16 Outlet water temperature too high Reset; check temperature setting Code repeats
19 Electrical short (often appears as soon as water flows)   Always
25 Condensate drain safety switch tripped Clear a clogged or frozen condensate line; check the condensate pump has power Drain is clear and code persists
32, 33, 34 Thermistor (temperature sensor) faults: outlet water, heat exchanger, combustion air   Always
38 Exhaust gas temperature sensor fault   Always
41 Freeze protection sensor fault   Always
51 Inlet water thermistor fault   Always
52 Gas valve or modulating valve signal fault   Always
54 Exhaust temperature too high Check vent for restrictions Code persists
57, 58 Burner or secondary heat exchanger overheat switch open (58 often from scale) Flush and treat hard water (58) Needs a technician reset and checks
61 Fan motor fault   Always
63 Recirculation setting or plumbing issue Make sure inlet and outlet valves are open; clean the inlet filter Persists
65 Water flow control (servo) fault Clean the inlet water filter Persists
70, 71 Gas solenoid valve fault   Always
72 Flame rod / flame sensing fault   Always
79 Leak detected inside the unit Turn off water and gas; look for leaks Always
FF Maintenance marker, not a fault None  

Code meanings from Rinnai’s “Troubleshooting TWH Diagnostic Codes” guide and Rinnai controller documentation. Exact meanings can vary slightly by model; check your owner’s manual.

The most common Rinnai codes explained

Code 11: no ignition

The heater tried to light but didn’t detect a flame. The most common causes are a closed gas valve, low gas pressure (for example, an empty propane tank), or air in a new gas line. Make sure gas is reaching other appliances, then reset. If it keeps happening, a technician should check gas pressure, the igniter and the flame rod.

Code 12: flame failure

The burner lit but the flame went out. Check the gas supply and look for blocked vents outside. Rinnai’s guide also points to grounding, wiring and the flame rod, which are technician checks.

Code 10: air supply or exhaust blockage

Check the intake and exhaust terminations outside for snow, ice, leaves, insects or bird nests, make sure the condensate drain isn’t backed up, and clean the unit’s air filter if it has one. If everything looks clear, the vent installation or fan needs professional inspection.

LC codes: scale buildup

LC means scale is building up inside the heat exchanger, common in hard water areas. Rinnai notes LC lets the heater keep running temporarily (pressing On/Off five times gives about 70 hours), but you need to flush the heat exchanger to clear it properly.

Code 25: condensate drain

On condensing models, a float switch shuts the heater off if condensate can’t drain. Check that the drain line isn’t clogged, kinked or frozen and that any condensate pump has power.

How to flush a Rinnai tankless water heater

  1. Turn off power to the heater and close the gas valve.
  2. Close the hot and cold isolation valves on the service kit.
  3. Connect hoses and a small submersible pump with a bucket of descaling solution or white vinegar, following your manual.
  4. Open the service ports and circulate the solution for about an hour (or as your manual specifies).
  5. Flush with clean water, clean the inlet filter, close the ports, reopen the valves and restore gas and power.

Most manufacturers recommend flushing at least once a year in hard water. See our tankless flushing guide and how to clean a tankless water heater.

Tankless flush kits on Amazon →  |  Descaling solution →

Frequently asked questions

How do I reset my Rinnai tankless water heater?

Turn off all hot water taps, then turn the controller off and back on with the On/Off button. If there’s no controller, briefly turn the power off and on. If the code returns after a few resets, call for service.

What does code 11 mean on a Rinnai?

No ignition. Check that the gas is on and supplied, then reset. Persistent code 11 needs a technician.

What does LC mean on a Rinnai water heater?

Scale buildup in the heat exchanger. Flush the unit with descaling solution and consider treating hard water.

Is a Rinnai error code covered by warranty?

Many part failures are, but damage from scale (LC codes) or improper installation may not be. Check your warranty and register the unit with Rinnai.

Sources: Rinnai “Troubleshooting TWH Diagnostic Codes” (Rinnai America), Rinnai controller and owner’s documentation. Gas appliance repairs should be done by qualified technicians. Exact codes and procedures vary by model.