Disclosure: As an Amazon Associate, Sweet Home Advisor earns from qualifying purchases. If you buy through links on this page, we may earn a small commission at no extra cost to you.
To test a water heater element, turn off the breaker, confirm there’s no power, disconnect the element’s wires, and measure across its two terminals with a multimeter set to ohms. A good 240-volt element reads about 10 to 16 ohms depending on wattage; a reading of infinity (open) means it’s burned out. Also check from each terminal to the tank: any continuity means the element is shorted. To replace it, drain the tank below the element, unscrew it with a 1-1/2 inch element socket, fit the new one with a new gasket, and refill the tank completely before turning the power back on.
Safety first
- Electric water heaters run on 240 volts. Turn off the breaker and test with a meter that the power is off before touching wires.
- Never turn the power on until the tank is full of water. Running an element dry burns it out in seconds.
- If you’re not comfortable working with electricity, call a licensed plumber or electrician.
Signs of a bad water heater element
| Symptom | Likely cause |
|---|---|
| No hot water at all | Upper element or upper thermostat failed (or the reset button tripped) |
| Hot water runs out quickly | Lower element failed |
| Lukewarm water | One element failed or heavily scaled |
| Breaker keeps tripping | Element shorted to the tank |
| Higher electric bills | Scaled elements heating slowly |
Based on Ferguson’s water heater element testing guide.
Before testing, press the red reset button on the upper thermostat (under the top access panel, with power off). If it trips again, an element or thermostat may be faulty. See our thermostat testing guide.
Tools you need
- Digital multimeter (ohms and AC voltage)
- Insulated screwdriver
- 1-1/2 inch water heater element socket (for replacement)
- Garden hose and bucket (for replacement)
- Replacement element matching your voltage and wattage, with a new gasket
Multimeters on Amazon → | Element sockets →
How to test a water heater element
- Turn off the breaker for the water heater.
- Remove the access panel, fold back the insulation and remove the plastic safety cover. There are usually two elements, upper and lower.
- Confirm the power is off: set the meter to AC volts and test across the thermostat terminals. It must read zero.
- Disconnect one wire from the element (or both) so other parts don’t affect the reading.
- Measure resistance: set the meter to ohms and touch the probes to the two element screws.
- Test for a short: touch one probe to an element screw and the other to the bare metal of the tank or the element’s mounting flange. Repeat on the other screw.
- Repeat for the other element.
Water heater element resistance chart
| Element (240 V) | Expected resistance |
|---|---|
| 3,500 watts | About 16.5 ohms |
| 4,500 watts | About 12.8 ohms |
| 5,500 watts | About 10.5 ohms |
Calculated as volts squared divided by watts (240 x 240 / watts). The wattage is printed on the element and the heater’s rating label. Readings within about 10% are normal.
| Reading | Meaning |
|---|---|
| Within the expected range, no continuity to the tank | Element is good |
| Infinity / OL (open) | Element is burned out; replace it |
| Close to 0 ohms across terminals | Element is shorted; replace it |
| Any continuity from a terminal to the tank | Grounded (shorted) element; replace it |
How to replace a water heater element
- Turn off the breaker and confirm there’s no power.
- Close the cold water supply valve.
- Drain the tank below the element: attach a hose to the drain valve, open a hot tap in the house, and open the drain. For the lower element, drain the tank fully. See our draining guide.
- Disconnect the wires and unscrew the old element counterclockwise with the element socket.
- Clean the threads and the gasket surface on the tank.
- Install the new element with its new gasket, starting it by hand to avoid cross-threading, then snug it with the socket. Don’t overtighten.
- Refill the tank: close the drain, open the cold supply, and keep a hot tap open until water flows steadily with no air. Check for leaks at the element.
- Reconnect the wires, replace the safety cover, insulation and panel, then turn the breaker on.
- Wait about an hour and check the hot water temperature.
Match the replacement to the old element’s voltage, wattage and style (screw-in is most common). If the elements are heavily scaled, flush the tank at the same time; see water heater popping noises.
4,500 W 240 V elements on Amazon →
Repair or replace the water heater?
An element costs little and is a common DIY repair. But if the tank is leaking, rusted or more than about 10 to 12 years old, replacing the whole heater may make more sense. Check its age with our serial number guide and see the replacement cost.
Frequently asked questions
How do I know which element is bad?
Test both. As a rule of thumb, no hot water points to the upper element or thermostat; hot water that runs out quickly points to the lower element.
Can I test a water heater element without a multimeter?
Not reliably. A non-contact voltage tester can show whether power reaches the element, but only a multimeter tells you whether the element itself is good.
Can I replace a water heater element without draining the tank?
For the upper element you only need to drain below it. Draining is always needed for the lower element. Some people swap elements quickly without draining, but it’s messy and risky.
How long do water heater elements last?
Often 6 to 10 years or more, but hard water and sediment shorten their life.
Sources: Ferguson “Water heater element testing and replacement”; manufacturer service manuals. Resistance values calculated from Ohm’s law. Electrical work can be dangerous; follow your heater’s manual.