To replace a water heater’s temperature and pressure (T&P) relief valve, turn off the power or gas, shut off the cold water, drain the tank until the water is below the valve, remove the discharge pipe, and unscrew the old valve. Wrap the new valve’s threads with thread-seal tape, screw it in tightly, reattach the discharge pipe, then refill the tank completely before restoring power or gas. Use a replacement with the same ratings as the original, usually 150 psi and 210°F. If the old valve was dripping, find out why before you replace it.
Important safety notes
- The T&P valve is the safety device that stops a water heater from building dangerous pressure. Never remove it, plug it or cap its discharge pipe.
- The water and the valve can be scalding hot. Let the water cool or wear gloves.
- Check local code: some areas require a licensed plumber for this work.
Why is my T&P valve leaking?
| Symptom | Likely cause | Fix |
|---|---|---|
| Drips after the heater runs | Thermal expansion in a closed system | Install an expansion tank |
| Leaks when house pressure is high | Water pressure above about 80 psi | Adjust or install a pressure-reducing valve |
| Discharges hot water or steam | Water too hot (thermostat fault) | Turn off the heater and call a pro |
| Constant drip with normal pressure and temperature | Worn valve or debris on the seat | Replace the valve |
| Leaks after you test it | Sediment stopped it reseating | Test again to flush it, or replace |
A new valve won’t stop drips caused by high pressure or thermal expansion; fix the cause first. See our water heater leaking guide.
Choosing a replacement T&P valve
- Match the ratings on the old valve’s tag: most residential valves are rated at 150 psi and 210°F.
- Match or exceed the heater’s BTU (or kW) input, shown on the valve tag and the heater’s rating label.
- Match the thread size (usually 3/4 inch) and the probe length.
- Use the manufacturer-approved part where possible; Sears PartsDirect advises replacing a leaking or damaged valve with the manufacturer-approved part.
T&P relief valves on Amazon → | Water pressure gauges →
How to replace a water heater T&P valve
- Turn off the heat: switch off the breaker for an electric heater, or set a gas heater to Off or Pilot.
- Shut off the cold water supply to the heater.
- Drain some water: attach a hose to the drain valve, open a hot tap in the house, and drain about 10 gallons, or until the water level is below the T&P valve opening (it’s usually on the top or upper side of the tank).
- Disconnect the discharge pipe from the valve.
- Unscrew the old valve with a pipe wrench, turning counterclockwise.
- Prepare the new valve: wrap the threads with thread-seal tape (or use pipe dope rated for potable water), keeping it off the first thread.
- Install the new valve and tighten it firmly, with the outlet pointing in the same direction as before.
- Reattach the discharge pipe. It should be the same size as the valve outlet, run downward, and end 6 inches or less above the floor or a drain, without threads or a cap on the end. Follow your local code.
- Refill: close the drain valve, open the cold supply, and let water run from the hot tap until it flows steadily. Check for leaks.
- Restore power or gas only after the tank is full.
Steps based on Sears PartsDirect’s T&P valve replacement guide and manufacturer installation manuals.
How to test a T&P valve
Many manufacturers recommend testing the valve periodically, often once a year. Place a bucket under the discharge pipe, lift the lever for a few seconds to let water flow, then let it snap shut. If water keeps dripping after the test, try once more to flush out debris; if it still leaks, or no water comes out at all, replace the valve.
T&P valve replacement cost
The valve itself is an inexpensive part; a plumber’s service call to replace it costs more because of labor. If the heater is old and the valve is one of several problems, compare the cost of a new water heater. You can check your heater’s age with our serial number guide.
Frequently asked questions
Can I replace a T&P valve without draining the tank?
You need the water level below the valve. On most heaters that means draining a few gallons, not the whole tank.
Is it normal for a T&P valve to drip?
No. Occasional drips usually mean thermal expansion or high pressure; a constant drip means a worn valve. Either way, find the cause.
How long does a T&P valve last?
Often as long as the water heater, but mineral buildup can make it stick or leak. Testing it periodically helps.
Can I plug a leaking relief valve?
Never. Plugging or capping the valve or its discharge pipe removes the heater’s protection against dangerous pressure.
Sources: Sears PartsDirect “How to replace a water heater temperature and pressure relief valve”; A. O. Smith leaking water heater guidance; manufacturer installation manuals; local plumbing codes. Gas work should be done by qualified professionals.